Vapor Pin and Soil Gas Well Sampling

by Derrick Lingle
Mar 11, 2020
0

Vapor Pin Sampling_2020

Due to the volatile nature of solvent and petroleum-related contaminants, the volatilization to indoor air pathway (VIAP) is often relevant during environmental investigations at manufacturing facilities, dry cleaners, and gas stations. The concern is that vapors, which off-gas from a contaminant body, will seep into a building and create unsafe conditions for the inhabitants. If groundwater or soil contaminant concentrations exceed criteria for the VIAP in close proximity to a building structure (existing or future), additional vapor characterization may be necessary.

To further assess the VIAP, a soil gas (vapor in the subsurface) sample can be collected from a shallow soil gas well (approximately 5 feet deep) immediately outside the footprint of a building or from a Vapor Pin®. A Vapor Pin® allows for the collection of a soil gas sample directly beneath a foundation floor (known as a sub-slab soil gas sample) by installing a brass pin into the floor and then drawing a sub-slab soil gas sample through the pin. Soil gas wells can also be utilized at a vacant property where a future structure is planned or along a utility corridor that may serve as a preferential pathway for vapors.

At two of Envirologic's recent site investigations where gasoline was released into the subsurface, potential VIAP concerns warranted additional investigation. At one of the locations, sub-slab soil gas samples were collected after elevated contaminant concentrations were identified in groundwater and soil samples near the building. Results from the sub-slab samples, in conjunction with additional lines of evidence, suggest that the VIAP does not present an unacceptable exposure risk, and no further evaluation is needed with respect to this pathway. At the second site, soil gas wells were installed immediately outside of the on-site building. Although initial soil gas results indicate a potential VIAP issue, Envirologic is currently working with the liable party to address the exposure risk through additional characterization.

Due to biodegradation, soil gas concentrations (particularly from petroleum-related contaminants) typically decrease as vapors migrate toward the surface. The benefit to relying on shallow soil gas data, as opposed to soil or groundwater data collected at depth, is that the near-surface soil gas samples are more representative of conditions immediately beneath the floor of a building. If soil gas results indicate the potential for an unacceptable exposure risk, the focus for the VIAP investigation shifts toward indoor air sampling (which has limitations), remediation (excavation, air sparging, etc.), or mitigation (installation of a vapor barrier, sub-slab depressurization system, etc.).

There are often sampling needs as part of an environmental investigation; let Envirologic support your project using our experienced Vapor Intrustion Services team. For a complete list of our Field Services, please visit our website or contact a member of our team at (269) 342-1100 or information@envirologic.com.


Back to Recent Posts >


Post a Comment

10 + 7 =

Email Alerts

Subscribe to email alerts from the Envirologic Blog.


Categories

Archive

View Archived Posts

Tags

vapor pin  soil gas  contaminants  vapors  groundwater  mitigation  remediation  sub-slab depressurization system  pathway 


Tell Us About Your Project

We'll share our expertise, create a quote and find the best solution for you.

Contact Envirologic
© 2020 envirologic  |  2960 Interstate Pkwy
 |  Kalamazoo, MI 49048
P 800.272.7802  |  F 269.342.4945
This website is Eco-Friendly Envirologic on Facebook Envirologic on Twitter Envirologic on Linked In